Fire Alarm Control Panel Accessories

Analog

FNP-LED- Graphix LED Display

FNP-LED- Graphix LED Display

DESCRIPTION

The FNP-LED system uses flexible, optic light guides to illuminate areas on a floor plan, laid over a high resolution grid. This unique system dispenses completely with wiring and enables indicators to be moved, removed or added onsite without the need for any wiring. All indicators can be configured to operate upon any event type and at point, zone or group level via the powerful and intuitive Loop Explorer configuartion tool. FNP-LED can be supplied with or without optional LED’s and controls. Optional LED’s indicate Power On, Fire, Trouble and Disablements and optional controls are for Alarm Silence, Buzzer Silence, Lamp Test, and Reset. Housed in an attractive, slimline enclosure to match FireNET Plus Fire Alarm Panels. High quality, full color floor plans provide a clear and geographical indication of event activation, which enables fast identification of the Fire Alarm source.

STANDARD FEATURES

• Available in Red and Charcoal Gray
• Up to 504 LED’s can be controlled with FireNET Plus Panel
• Available in 3 different size enclosures
• LED’s comes in 3 different colors: Red, Green, or Yellow
• FNP-LED can be easily upgraded onsite with minimal cost and effort


FN-LCD-N – LCD Network Annunciator

FN-LCD-N - LCD Network Annunciator

DESCRIPTION

The FN-LCD-N type LCD network annunciator is designed to be used with the FireNET analog addressable system. It allows for remote access, monitoring & control of the FireNET system throughout the building.

The FN-LCD-N is a true network annunciator that can access, monitor & control any or all FireNET panels in the network. Each FN-LCD-N is completely independent. The highly intuitive user interface and 320 character LCD display of the FN-LCD-N is exactly the same as the FireNET panel. In addition to routing any panel in the network to the FN-LCD-N, every event category within each panel can also be individually routed, as well as routing of all remote control functions (reset, alarm silence, re-sound alarm) from individual panels.

The FN-LCD-N supports the same RS485 expansion port as the FireNET panel, allowing for FireNET expansion boards and accessories to be connected to the network annunciator. The FN-LCD-N also has (4) output relays for fire, supervisory, trouble & auxiliary. The relays are programmable (except supervisory).
Security is established by the use of a password or firefighters enable key. Designed to be aesthetically pleasing, the FN-LCD-N is available in charcoal grey or red and can be surface or flush mounted using a standard trim ring kit.

STANDARD FEATURES

• UL 864 9th edition Listed
• 320 character liquid crystal display (8 line x 40 character)
• LED indicators for Fire, Supervisory Alarm, Pre- Alarm, Fire Output Active, Power On, On Test, Panel Sounder Silenced, Delay Active, More Events, Point Bypassed, General Trouble, Power Trouble, System Trouble & NAC Trouble
• Dual RS485 ports for primary fire network
• RS485 slave bus for expansion – up to 32 FN-4127-IO boards or up to 15 FN-LCD-S serial annunciators and up to17 FN-4127-IO boards
• 2 built-in RS-232 interfaces for programming via a PC and serial printer interface
• 4 on board programmable Form C relays rated at 1 Amp at 30VDC (Fire, Supervisory, Trouble & Auxiliary)
• Same controls as the FireNET fire panel (Reset, Panel Sounder Silence, Lamp Test, Alarm Silence, Re-sound Alarm, Fire Drill, Programmable Function, More Events, More Fire Events, Enter & Exit)
• Local piezo sounder for event notification
• Supports user codes & firefighter key to enable access & controls
• Powered by FireNET Aux 24VDC or UL fire listed Aux. 24VDC supply
• Available in red or charcoal, and can be surface or flush mounted (using trim ring)
• True network annunciator, any or all panels can be routed to the FN-LCD-N. In addition, each event category can be individually routed to the FN-LCD-N
• Up to (64) FireNET panels & FN-LCD-N’s can be networked together in any combination
• 500mA of auxiliary power available rated at 24VDC
• Auto-learn feature
• Built-in help & alarm information screens
• Fire drill function
• Each FN-LCD-N is completely independent
• The FN-LCD-N can be configured to remote reset, silence, resound, any or all panels on the network in any combination


FN-LCD-N – LCD Network Annunciator

FN-LCD-S - Serial LCD Annunciator

DESCRIPTION

The FN-LCD-S serial annunciator provides a convenient and cost effective remote annunciator solution. Up to 15 FN-LCD-S annunciators can be connected to the slave RS-485 port of the FireNET control panel or network annunciator. The FN-LCD-S’s large 320 character display and navigation buttons are a complete mimic of the FireNET control panel display. The use of a common interface allows the user to easily operate the FN-LCD-S as if he were operating the FireNET control panel directly.

Security is established by the use of a password or firefighters enable key. Designed to be aesthetically pleasing, the FN-LCD-S is available in charcoal grey or red enclosures. The FN-LCD-S can be surface or flush mounted without the need for a trim ring.

STANDARD FEATURES

• UL 864 9th edition Listed
• Large 320 character liquid crystal display (8 line x 40 character) allows viewing of system status
• LED indicators for Fire, Supervisory Alarm, Pre- Alarm, Fire Output Active, AC Power On, On Test, Panel Sounder Silenced, Delay Active, More Events, Point Bypassed, General Trouble, Power Trouble, System Trouble & NAC Trouble
• Same controls as the FireNET fire panel (Reset, Panel Sounder Silence, Lamp Test, Alarm Silence, Re-sound Alarm, Fire Drill, Programmable Function, More Events, More Fire Events, Enter & Exit)
• Up to 15 FN-LCD-S serial annunicators may be connected to a FireNET control panel or network annunciator
• Resides on the FireNET slave RS-485 line
• Local piezo sounder for event notification
• Supports user codes & firefighter key to enable access & controls
• Powered by FireNET Aux 24VDC or UL fire listed Aux. 24VDC supply
• Available in red or charcoal, and can be surface or flush mounted
• Built-in help & alarm information screens
• Fire drill function


FN-4127-IO 16 Channel Input/Output Board (RS-485 Bus Device)

FN-4127-IO

DESCRIPTION

The FireNET FN-4127-IO is a 16 channel Input/Output board that provides powerful input/output expansion & addition to the FireNET system allowing up to thirty two I/O boards to be connected to each FireNET panel within the FireNET network. Every I/O board connected to any panel is available to the entire network, which allows for network wide input/output mapping. Typical uses include graphical LED map displays/annunciators, tabular LED zone display/ annunciators, input/output logic to & from the fire system for secondary use (I/O board points cannot be used for primary fire initiation inputs or notification outputs) such as access control, burglar, CCTV, intercom, voice, or other 3rd party systems. Each channel can be configured to produce a variety of input actions or respond to a variety of output categories or logic. All channels can trigger, or react from, network wide cause and effect logic depending on their configuration. The flexibility of these boards is further enhanced by the fact that each of the channels is configurable as either an input or an output. Connection can be achieved through a simple two wire RS485 communications protocol and two wire power input. I/O boards can be mounted locally in the control panel or distributed on a bus up to 4,000ft from the panel when using the FN-ACC accessory enclosure.

STANDARD FEATURES

• 16 channels of input/output points
• 32 I/O boards per FireNET panel (512 channels of input/output points)
• Each channel configurable as input or output point
• Inputs are opto-isolated non-supervised pulldown type triggered by “dry” contact from input source
• Outputs are open collector transistor pulldown type (100mA max each) that provide “wet” voltage output
• Simple 4 wire connection to control panel (2 for power, 2 for data)
• All inputs/outputs can be assigned to global functions, any event category, and used in network wide Cause & Effect logic
• Can be mounted locally within control panel enclosure or remotely via FN-ACC accessory enclosure up to 4000ft from the panel
• Each I/O board has a unique address 1-32 (set via DIP switch) on the I/O Comms Bus
• Input/Outputs are for secondary use, not for primary fire initiation inputs or notification outputs
• Two LED’s are provided for communication status


FN-4127-SLC Dual Loop Expander

FN-4127-SLC Dual SLC Loop Expander

DESCRIPTION

The model FN-4127-SLC Dual SLC Loop Expander is a two loop expander board that increases the standard FireNET loop capacity from 2 to 4 loops.

The FN-4127-SLC can be added at the factory or installed in the field, and mounts within the main control board location as a piggy-back board. By adding the FN-4127-SLC, the FireNET capacity is increased from 254+254 to 508+508 analog addressable points within the overall 800 address/ sub-address limit. The FN-4127-SLC has the same functionality as the built-in SLC loops. The FN-4127- SLC utilizes Hochiki’s robust DCP loop protocol for highly reliable and fast alarm reporting without the need for shielded or twisted pair wiring for the SLC loops.

STANDARD FEATURES

• Adds two SLC loops to a two loop FireNET control panel
• Each SLC loop is capable of 127 sensors/ modules, plus 127 analog sounder bases, for a potential total of 254 addresses per loop (127+127 per loop)
• FN-4127-SLC can be added at the factory or installed in the field
• Supports Class A and B wiring methods per NFPA72 Styles 4, 6, and 7 (with isolators)
• Fully supervised & power limited SLC loops
• Supports Hochiki’s DCP (Digital Communication Protocol) loop protocol
• Same functionality as built-in SLC loops of FireNET control panel
• One SLC expander (maximum) may be added per FireNET control panel
• Each SLC loop is completely independent and autonomous
• Uses standard wire, no shielded or twisted pair required on SLC loops


FN-CTM City Tie Module

FN-CTM City Tie Module

DESCRIPTION

The FN-CTM City Tie Module is used to connect a Fire Alarm Control Panel to a Local Energy type City Tie Monitoring circuit. The FN-CTM City Tie Module circuit provides the power necessary to trip the Master Box Trip Coil when the Fire Alarm Control Panel goes into alarm.

The City Tie Circuit is capable of providing 1A for 0.5 seconds to operate the Master Box Trip Coil. The wiring is supervised to the Master Box by placing the Fire Alarm Control Panel EOL device on the terminals of the FN-CTM City Tie Module.

STANDARD FEATURES

• Interfaces Fire Alarm Control Panels to a Local Energy type City Tie monitoring circuit
• Integrates Fire Alarm Control Panel EOL device into module for supervision of interface wiring
• Wide operating voltage
• Power limited operation
• Transient protection
• Terminals accept up to 14 AWG wire
• Mounts to a standard 4″ electrical back box


FN-DAC – Digital Alarm Communicator

FN-DAC - Digital Alarm Communicator

DESCRIPTION

The FN-DAC Digital Alarm Communicator reports Alarm, Trouble, Supervisory and other system events using PSTN telephone lines. Events are reported to a compatible central station monitoring receiver. The communicator may be configured to report by zone or by address (point). The FN-DAC is installed in the FireNET enclosure, or may alternately be installed in the FN-LCD-N network annunciator. The FN-DAC receives data and power from the FireNET panel, or power may be provided by a UL listed 24 VDC regulated power supply. Events from one or more networked panels may be reported using just one FN-DAC communicator.

The FN-DAC contains a built-in modem which allows a remote user to connect to the panel(s) to view current status, panel event history and sensor analog values. Panel programming data may also be copied or sent to one or more network
panels.

STANDARD FEATURES

• Contact ID and SIA reporting formats
• UL 864 9th Edition listed
• Programmable from FireNET control panel or by using Loop Explorer
• Zone or Address (Point) reporting
• Remote upload / download and diagnostic tools
• Backup and Duplicate reporting
• Programmable daily test report interval
• Quick installation in FireNET enclosure

Conventional

HDM-1008 Eight Initiating Circuit Module

HDM-1008 Eight Initiating Circuit Module

GENERAL

The HDM-1008 Module provides the HCP-1000 Fire Alarm Control panels with up to 8 Class B (Style B) or 4 Class A (Style D) Initiating Circuits which can be configured for Alarm, Supervisory, Waterflow or Trouble circuits.

APPLICATIONS

The HDM-1008 provides up to eight zones of Class B (Style B) or four Class A (Style D) Initiating circuits. Each of the circuits can be configured as either Alarm, Supervisory, Waterflow or Trouble zones. Each circuit can handle both powered devices such as smoke detectors and non-powered devices such as heat detectors, pull stations, waterflow devices, tamper switches, etc.

INSTALLATION

The HDM-1008 consists of a PC board which mounts at the bottom of the chassis. The PC board is connected via cables to the board on the main chassis. Space is provided on the front panel allowing the application of slide-in labels for initiating zone description. Labels are provided with each chassis. Removable terminal blocks are provided for easy connection of field wiring and servicing.

STANDARD FEATURES

• Eight Class B (Style B) or 4 Class A (Style D) Initiating Circuits which can be configured as Alarm, Supervisory, Waterflow or Trouble Circuits
• Bi-Colored Alarm/Supervisory and Trouble LED provided for individual annunciation of each zone
• Slide-in labels for zone identification
• Programmable as Supervisory Circuit for Latching and Non-Latching
• All circuits are power limited for use with limited energy cable
• Removable terminal blocks for ease of wiring and servicing
• Extensive transient protection of all circuits


HRAM-208 Remote Annunciator

HRAM-208 Remote Annunciator

DESCRIPTION

The HRAM-208 Remote Annunciator is a multiplexed annunciator that provides control, indication of common annunciator functions and 8 zones of LED annunciation. The HRAM-208 Remote Annunciator comes standard with 8 Bi-Colored LEDs which are automatically configured for either Alarm (Red) or Supervisory (Amber) to match the HCP-204 Series Fire Alarm Control Panels. The unit mounts in a 4 gang electrical box.

The HRAM-208 also comes equipped with common control switches for Signal Silence, Buzzer Silence, Lamp Test and System Reset. In addition it has LEDs for Power On, Common Trouble and Signal Silence. The HRAM- 208 is equipped with a keyswitch which allows for the enabling and disabling of Common Control functions.

All points are identified by the corresponding label the slides in beside the LED. Up to three HRAM-208 remote annunciators can be used with the HCP-204 and HCP-204E Fire Alarm Control Panels.

STANDARD FEATURES

• 8 Bi-Colored LEDs which are automatically configured for either Alarm (Red) or Supervisory (Amber) to match the Series 200 Fire Alarm Control Panels
• Signal Silence, Buzzer Silence, Lamp Test and System Reset switches
• LEDs for Power On, Common Trouble and Signal Silence
• Equipped with a keyswitch which allows for enabling and disabling of the Common Control functions
• Each point can be identified by the corresponding label beside the LED
• Mounts in a standard 4-gang electrical box
• Up to three HRAM-208 Remote Annunciators can be used with the HCP-204 and HCP 204E Fire Alarm Control Panels
• Not compatible with the HCP-202 series


HSGM-1004 Four Indicating Circuit Module

HSGM-1004 Four Indicating Circuit Module

GENERAL

The HSGM-1004 Module provides the HCP-1000 Fire Alarm Control panels with up to 4 Class A or B (Style Z or Y) Indicating Circuits.

APPLICATIONS

The HSGM-1004 provides up to four indicating circuits each rated at 1.7 Amps to signal devices such as strobes, bells, horns, etc. Each of the indicating circuits can be configured as non-silenceable (steady) or silenceable. In addition, each circuit comes with an individual trouble indicator. All circuits are power limited for use with limited energy cable.

INSTALLATION

The HSGM-1004 consists of a PC board which mounts at the bottom of the chassis. The PC board is connected via cables to the board on the main chassis. Space is provided on the front panel allowing the application of slide-in labels for indicating zone description. Labels are provided with each chassis. Removable terminal blocks are provided for easy connection of field wiring and servicing.


HRA-1000 Remote Annunciators

HRA-1032

HRAM-1032

HRAM-1032- Main Annunciator Chassis

The HRAM-1032 Main Annunciator Chassis is an expandable module used in the HRA-1000 Series Remote Annunciators to provide control, indication of common annunciator functions and up to 32 points of annunciation. The HRAM-1032 comes standard with Bicolored LEDs which are automatically configured for either alarm (Red) or Supervisory (Amber) to match the HCP-1000 Fire Alarm Control Panel configuration. Each display point can be identified by the slide-in label that slides in beside the LED. Equipped with sealed membrane-like buttons and LED indicators, the HRAM- 1032 has a Local Buzzer as well as indicators for A.C. On, Common Trouble, Remote Failure, Aux. Disconnect, Acknowledge, General Alarm, Signal Silence and Test/ Configuration mode. In addition it has controls for System Reset, Lamp Test, Fire Drill, Auxiliary Disconnect, Buzzer Silence, Signal Silence, General Alarm and Acknowledge. It occupies one slot in the HBB-1000 enclosures.

HRA-1032

HRAX-1048

HRAX-1048 – Adder Annunciator Chassis

The HRAX-1048 Adder Annunciator Chassis is used in the HRA-1000 Series Remote Annunciators to provide 48 additional points of annunciation. The HRAX-1048 is an expandable annunciator module which can be connected to an HRAM-1032. A maximum of four HRAX- 1048 can be connected to the HRAM-1032 Main Annunciator Chassis. As with the HRAM-1032 Main Annunciator Chassis, the HRAX-1048 has Bi-colored LEDs which are automatically configured for either Alarm (Red) or Supervisory (Amber) to match the HCP-1000 Fire Alarm Control Panel configuration. Each display point can be identified by the slide-in label that slides in besides the LED. It occupies one slot in the HBB-1000 enclosures.

STANDARD FEATURES

• Large capacity of annunciation
• Bi-Colored LEDs
• Slide-in labels for each display point
• Sealed membrane-like buttons and LED indicators
• Each annunciation point is automatically selected for either Alarm (Red) or Supervisory (Amber) to match the HCP-1000 Fire Alarm Panel configuration
• LEDs for A.C. On, Common Trouble, Remote Failure, Aux. Disconnect, Ackowledge, General Alarm, Signal Silence and Test/Config Mode
• Controls for System Reset, Lamp Test, Fire Drill, Aux. Disconnect, Buzzer Silence, Signal Silence, General Alarm and Ackowledge
• Three sizes of enclosures


HCP-1000 Auxiliary Modules

GENERAL

The Series 1000 Microprocessor Based Fire Alarm System can be configured to meet virtually any requirements. To facilitate this flexibility, the panel has a number of add-on modules which allow the system to perform certain functions.

The following modules have been designed to adapt the system to suit the particular requirements of a building.

HRM-1008

HRM-1008

HRM-1008
Eight Relay Circuit Module

The HRM-1008 Eight Relay Circuit Module provides eight
programable Form C relays. Each relay is rated for 28
VDC @ 1 Amp max. Each relay is annunciated for
configuration on the front display board of the HMCC-
1024-6 or HMCC-1024-12 Main Chassis or HECH-1048
Expander Chassis. The HRM-1008 Relay Adder Module
comes with removeable terminal blocks for easy wiring
and servicing. The module connects via cable to the
board on the main or expander chassis.

HPR-100

HPR-100

HPR-100
Polarity Reversal & City Tie Module

The HPR-100 Polarity Reversal & City Tie Module allows connection to two different types of monitoring systems. The City Tie provides an output of 24 VDC at 210 mA max. The module supervises the City Tie connection and will provide a system trouble if not connected. A terminating resistor is supplied with the module. The Polarity Reversal provides a 24 VDC output for normal condition and a polarity reverse 24 VDC output for alarm. The module is also capable of transmitting a system trouble “Zero Volts.” This option is jumper selectable. The output current is limited to 8 mA.

HDACT-100

HDACT-100

HDACT-100
Digital Alarm Communicator Transmitter/Dialer Module

The HDACT-100 Digital Alarm Communicator Transmitter/
Dialer Module allows the HCP-1000 Fire Alarm Control
Panels to use one or two phone lines to call a Central
Station and report a local Alarm, Trouble or Supervisory
condition. Requiring two supervised telephone lines, the
HDACT-100 can be programmed to use the Security
Industry Association (SIA) Digital Communication
Standard (DCS) and Ademco Contact ID protocols. The
HDACT-100 is powered by the HCP-1000 Fire Alarm
Control Panels and communicates with them via an RS-
485 Interface. The HCFG-100 Configuration & Diagnostic
Tool is required to program the HDACT-100.

HDACT-100U

HDACT-100U

HDACT-100U
Universal Digital Alarm Communicator Transmitter/Dialer Module

The HDACT-100U Universal Digital Alarm Communicator
Transmitter/Dialer Module allows the HCP-1000 Fire Alarm Control Panels to use one or two phone lines to call a Central Station and report a local Alarm, Trouble or Supervisory condition per zone. Requiring two supervised telephone lines, the HDACT-100U can be programmed to use the Security Industry Association (SIA) Digital Communication Standard (DCS) and Ademco Contact ID protocols. The HDACT-100U is powered by the HCP-1000 Fire Alarm Control Panels and communicates with them via an RS-485 Interface. The HCFG-100 Configuration and Diagnostic Tool is required to program the HDACT-100U.


CP-200 Auxiliary Modules

GENERAL

The HCP-200 Microprocessor Based Fire Alarm System can be configured to meet virtually any requirements.

The following modules have been designed to adapt the system to suit the particular requirements of a building.

HDM-204

HDM-204

HDM-204
Four Initiating Circuit & Two Indicating Circuit Module

The HDM-204 Module provides the HCP-204E Fire Alarm Control Panel with up to 4 Class B (Style B) or 2 Class A (Style D) Initiating Circuits. In addition it provides up to 2 Class A/B (Style Z/Y) Indicating Circuits which are rated for 1.7 Amps each. Each of the indicating circuits can be configured for silenceable or non silenceable. In addition each circuit comes with an individual trouble indicator. All circuits are power limited for use with limited energy cable. The HDM-204 consists of a PC board which mounts at the bottom of the chassis. The PC
board is connected via cables to the board on the main chassis.

 

HRM-204

HRM-204

HRM-204
Auxiliary Quad Relay Module

The HRM-204 Auxiliary Relay Module provides the HCP-200 Series with four configurable auxiliary relays. The relays can be configured for either relay per zone, Common Alarm relay(s) or Common Supervisory relay(s). Each relay is rated for 28 VDC @ 1 Amp max. The module is mounted on the top of any detection module, with hardware provided for the module. Requires one HCH-429 Accessory Mounting Plate when HRM-204 is mounted in the HCP-202 or HCP-204.

 

 

HRM-208

HRM-208

HRM-208
Eight Relay Module

The HRM-208 Auxiliary Relay Module provides the HCP-200 Series with eight configurable auxiliary relays. The relays can be configured for either relay per zone, Common Alarm relay(s) or Common Supervisory relay(s). Each relay is rated for 28 VDC @ 1 Amp max. The module is mounted on the top of any detection module, with hardware provided for the module. Requires one HCH-429 Accessory Mounting Plate when an HRM-208 is mounted in the HCP-202 or HCP-204.

 

 

HPR-100

HPR-100

HPR-100
Polarity Reversal & City Module

The HPR-100 Polarity Reversal & City Tie Module allows connection to two different types of monitoring systems. The City Tie provides an output of 24 VDC at 210 mA max. The module supervises the City Tie connection and will provide a system trouble if not connected. A terminating resistor is supplied with the module. The Polarity Reversal provides a 24 VDC output for normal condition and a polarity reverse 24 VDC output for alarm. The module is also capable of transmitting a system trouble “Zero Volts.” This option is jumper selectable. The output current is limited to 8 mA.

 

 

HDACT-100

HDACT-100

HDACT-100
Digital Alarm Communicator Transmitter/Dialer Module

The HDACT-100 Digital Alarm Communicator Transmitter/ Dialer Module allows the HCP-200 Fire Alarm Control Panels to use one or two phone lines to call a Central Station and report a local Alarm, Trouble or Supervisory condition. Requiring two supervised telephone lines, the HDACT-100 can be programmed to use the Security Industry Association (SIA) Digital Communication Standard (DCS) and Ademco Contact ID protocols. The HDACT-100 is powered by the HCP-200 Fire Alarm Control Panels and communicates with them via an RS-485 Interface. The HCFG-100 Configuration and Diagnostics Tool is required to program the HDACT-100.