VoiceNet

VoiceNET High Rise Voice Evacuation System

VoiceNET High Rise Voice Evacuation System

APPLICATION

Hochiki’s Reflective Beam Detector is designed for smoke detection in large spaces such as halls, warehouse, museums, theatres etc., where conventional point detection is impractical or more costly. The unit is not suitable for applications where strong or reflected sunlight is present, in these instances the SPB-24N should be considered. The unit detects smoke linearly over the protected range enabling early detection before the fire spreads. Compact design, good looks and flush mounting installation makes this unit ideal for fitting in areas where architectural considerations are important.

GENERAL DESCRIPTIONThe Hochiki VoiceNET High Rise Evacuation System operates in conjunction with the Fire Alarm Control Panel (FACP) in a building to provide automatic response to life safety emergencies. The Hochiki VoiceNET includes all necessary features to provide an effective voice evacuation system. The Hochiki VoiceNET can be custom configured to satisfy the needs of any high rise application.

Fire department authorities can easily take command of evacuation or relocation procedures and emergencies. Building management and fire
brigades can monitor and control emergency response even before the professionals arrive. The VoiceNET system includes capacity for 6 channels of simultaneous audio. This provides for evacuation, stay-in-place, or other public address announcements and automatic messages.

Fire Fighter Phones or Warden Stations may be included as required. Area-of-Rescue stations can reassure handicapped occupants that help is on the way.

ENGINEERING SPECIFICATIONSThe voice evacuation system shall be Hochiki Series VoiceNET FNV High Rise or approved equal. The VoiceNET FNV system shall include one Master Panel and one or more Distributed Panels. The system shall be microprocessor based, and shall be compatible for use with contact closures from the Fire Alarm Control Panel, (FACP). The system shall have a highspeed communication bus and have the capacity for 6 channels of audio and data on a single pair of wires. The field wiring for the communication bus may be configured for either Style “4″ or Style “7″ supervision. The system shall have the capacity for Fire Fighters Phone, Area-of- Rescue communication and also have the capacity for Fan & Damper control with monitored feedback. The system shall have a minimum capacity of 2028 monitor and control points.

The Master Panel shall contain an integral microphone, dual channel digital message repeater, (DMR) and digital tone generator, 120 VAC power supply, and battery charger. The system shall be modular in design, and shall be expandable such that additional system control points
may be configured. The system shall include integral self-diagnostic routines that shall continually monitor system status, and shall indicate the precise type of trouble conditions should they occur in the system. A trouble condition within the system shall cause a trouble indication to be transmitted to the FACP.

Distributed panels shall provide a minimum of 4 Class “B” speaker circuits, expandable to sixteen total. Alternately, panel may be configured for 4 Class “A” speaker circuits, up to 8 total. Panel may be configured for 1 to 8 amplifiers. Panel must provide up to 6 simultaneous audio channels, up to 8 Fire Phone circuits, up to 4 Area of Refuge circuits and up to two Control/Monitor loops. Amplifiers will contain their own power supplies, battery chargers and provide auxiliary power for other components. Speaker circuits shall be supervised for short and open circuit conditions, and shall be able to withstand transient or continuous short-circuit conditions without damage to the system. System may be configured for General Alarm All Call operation, Alarm by Zone or Floor Above / Floor Below as required. Contact closures shall allow immediate broadcast of an alarm signal and evacuation message to the appropriate area. Non-Alarm areas may receive alert tones and messages as required or activated by the FACP. The alarm signal/evacuation message shall be broadcast until the FACP is reset, or until emergency personnel interrupt the broadcast with a manual page. To prevent unauthorized tampering, the voice evacuation system shall disable the microphone if the microphone is keyed continuously for 3 minutes or more. Systems that do not have this feature shall not be acceptable.

STANDARD FEATURES

•Integrated Fire Phone, Area of Rescue
•and Fan & Damper Control capability
•Modular System – components added as needed
•Integrated 2 Channel Digital Message Repeater
•Live Microphone Page to any zone
•Fast RS-485 Communication Protocol
•Easy Installation and Operation
•Natural Sound Voice Recordings
•Built in Alarm and Alert Signals
•Up to 4 Minute Message Capacity
•Works with 12VDC or 24VDC Fire Alarm Panel
•Works with Analog/Addressable and
•Microprocessor based Fire Alarm Panels.
•3 Minute Message Restart on Microphone Key
•Made in the USA.


FNV-MP High Rise Voice Evacuation System Master Panel

FNV-MP High Rise Voice Evacuation System Master Panel

DESCRIPTION

The Hochiki FNV High Rise Evacuation System operates in conjunction with the Fire Alarm Control Panel (FACP) in a building to provide automatic response to life safety emergencies. The Hochiki FNV includes all necessary features to provide an effective voice evacuation system.

The Hochiki FNV can be custom configured to satisfy the needs of any high rise application.

Fire department authorities can easily take command of evacuation or relocation procedures and emergencies. Building management and fire brigades can monitor and control emergency response even before the professionals arrive. The FNV system includes capacity for 6 channels
of simultaneous audio. This provides for evacuation, stay-in-place, or other public address announcements and automatic messages.

Fire Fighter Phones or Warden Stations may be included as required. Area-of-Rescue stations can reassure handicapped occupants that help is on the way. Smoke control, stair pressurization, and HVAC shutdown can be completely automatic, unless controlled manually by management or fire authorities.

STANDARD FEATURES

•True Multiplex 6 Channel Distributed Audio
•Integrated Fire Phone, Area of Rescue
•and Fan & Damper Control capability
•Modular System – components added as needed
•Integrated 2 Channel Digital Message Repeater
•Live Microphone Page to any zone
•Fast RS-485 Communication Protocol
•Easy Installation and Operation
•Natural Sound Voice Recordings
•Built in Alarm and Alert Signals
•Up to 4 Minute Message Capacity
•Works with 12VDC or 24VDC Fire Alarm Panel
•Works with Analog/Addressable and
•Microprocessor based Fire Alarm Panels.
•3 Minute Message Restart on Microphone Key
•Made in the USA.
•Fully Supervised